Your Question: 
Hi all! I'm building a parameter file for data archiving, and I'm looking at an example that I was given when I was there for training. My question concerns the lines 4-7 of the parameter file, which in this example read: sensor sts2_gl 0 0001 axis Z 0 0 - 1 0 axis N 0 90 - 2 1 axis E 90 90 - 3 1 Presumably, these lines refer to a sts2 sensor. However I'm using the Guralp 3Ts. My questions: 1) what is the sensor code for the T3? 2) what are the axis definitions for the T3? Thanks -Christian Poppeliers
Asker Email: 
cpoppeli@gru.edu
Category: 
Data Archiving

Howdy Christian, the CMG3T is listed as a "cmg3t" in the batch file (I think you mean batch file as opposed to pf) and has the same axis statements as the sts2.